Inquiry
Form loading...

Products

01

Heavy Metal Manganese Rapid Test Card

2026-02-04

Heavy Metal Manganese Rapid Test Card is a rapid test kit based on Colloidal Gold Immunoassay methodology, used to detect residues of Heavy Metal Manganese Rapid Test Card in Water Food

view detail
02

Heavy Metal Mercury Rapid Test Card

2026-02-04

Heavy Metal Mercury Rapid Test Card is a rapid test kit based on Colloidal Gold Immunoassay methodology, used to detect residues of Heavy Metal Mercury Rapid Test Card in water、cereal
.

view detail
03

Heavy Metal Cadmium Rapid Test Card

2025-11-26

Quick answer: Heavy metal rapid test cards give an on-site screen for lead or cadmium in food and water within minutes, flagging lots for AAS or ICP-MS confirmation.

Key takeaways

  • Lead and cadmium accumulate in rice, spices, seafood and vegetables.
  • Portable cards support receiving, supplier audits and pre-shipment checks.
  • Use results to prioritise samples, not to certify compliance.

Lead and cadmium enter the food chain through soil, water, fertilisers and industrial processes. They accumulate in rice, spices, cocoa, seafood and leafy vegetables, and long-term exposure is linked to kidney damage, neurological effects and developmental harm in children. Regulators increasingly test at the point of import, so exporters need fast, practical screening tools.

What a heavy metal rapid test card does

Heavy metal rapid test cards provide an on-site screen for lead or cadmium in prepared food and water samples. The card format is simple: add the extracted sample, wait for the reaction and read the result visually. It gives QA teams an immediate indication of whether a lot is likely to meet a specification or needs laboratory confirmation.

Typical workflow

  • Collect and homogenise the sample
  • Perform the specified extraction and dilution
  • Apply the extract to the test card
  • Read the result within the stated time
  • Confirm any presumptive positive by AAS or ICP-MS

Where rapid cards help most

They are useful at receiving docks, in spice and rice processing, at seafood plants and during supplier audits. Because the cards are portable, a buyer can screen a shipment before accepting it, and a producer can check raw materials before blending.

Interpreting results responsibly

Rapid cards are screening devices, not substitutes for accredited analysis. Use them to prioritise samples, not to certify compliance. Keep records of lot numbers, operators and reading times, and send any positive or borderline sample to a laboratory for confirmation.

Learn more about the Heavy Metal Lead Rapid Test Card and the related cadmium and mercury cards.

Specification Detail
Targets Lead or cadmium (separate cards)
Sample Prepared food extracts or water
Time to result Minutes after extraction
Format Single-use test card
Confirmation AAS or ICP-MS

How do you design a heavy metal screening programme?

Heavy metal risk varies widely by product and origin. A risk-based programme focuses testing where contamination is most likely and uses rapid cards to decide which samples go to the laboratory.

Risk-map products and origins

Rice, cocoa, spices, seafood, leafy vegetables and water are common targets. Map each raw material to its origin, processing method and historical results. Regions with industrial pollution, mining or irrigation problems deserve more frequent checks.

Standardise sample preparation

Drying, grinding and extraction steps have a large effect on recovery. Write a short SOP for each matrix, train operators and use clean, metal-free consumables. Water samples need different preparation from solid foods, so keep the procedures separate.

Use screening to prioritise

Rapid cards are ideal for receiving and supplier audits. Send any positive or borderline result to an accredited laboratory for AAS or ICP-MS confirmation. Keep a small number of negative samples for verification testing to maintain confidence in the screening step.

Review suppliers and trends

Record results by supplier, origin and product. A quarterly review can reveal a persistent problem that single tests miss, and it gives buyers a factual basis for supplier conversations. Adjust testing frequency as the risk picture changes.

Common heavy metal screening mistakes

Using the same extraction for rice, spices and water, skipping homogenisation and treating a rapid card as a certificate are common errors. Another is ignoring borderline results because they are not clearly positive. Standardise preparation, re-test borderline samples and confirm every positive by AAS or ICP-MS.

  • No matrix-specific SOP
  • Contaminated grinding or digestion equipment
  • No negative control per batch
  • Results not linked to supplier and lot

Frequently asked questions

What is the detection limit of a heavy metal test card?

Detection limits depend on the card, the sample matrix and the extraction method. Check the kit insert and validate against the regulatory limit for your product.

Can a rapid card replace laboratory testing?

No. It is a screening tool. Any positive or borderline result should be confirmed by an accredited laboratory using AAS or ICP-MS.

Does the same card work for food and water?

Sample preparation differs between matrices. Follow the validated procedure for each sample type and do not assume transferability without verification.

Sources and further reading

view detail
04

T-2 Toxin Rapid Test Strip

2025-10-22

Quick answer: A T-2 toxin rapid test strip screens cereals and feed for T-2/HT-2 residues in minutes after extraction, helping QA teams prioritise lots for HPLC or LC-MS/MS confirmation.

Key takeaways

  • T-2 and HT-2 toxins are trichothecene mycotoxins found in cereals, especially oats and barley.
  • The EU sets indicative levels for T-2/HT-2 in cereals and cereal products.
  • The US does not have a general action level; monitoring and buyer specifications apply.
  • Rapid strips are for screening; confirm positives by LC-MS/MS.

Why T-2 toxin matters

T-2 and HT-2 toxins can cause feed refusal, gastrointestinal effects and reduced performance in livestock. They are found mainly in oats, barley, wheat and maize, especially in cool, wet growing seasons.

What the strip detects

The strip is a competitive immunoassay that detects T-2 toxin in the sample extract. A visible test line indicates a level below the cutoff; a faint or absent line is a presumptive positive.

US and EU rules at a glance

The EU has indicative levels for T-2/HT-2 in cereals and cereal products; these are not legal maximum levels but are used by regulators and buyers. The US relies on monitoring, FDA guidance and customer specifications rather than a single general limit.

How to use the strip

  • Grind and homogenise the cereal sample.
  • Extract and dilute per the insert.
  • Apply the extract and read within the window.
  • Confirm positives with LC-MS/MS.

Common mistakes

Sampling only the surface of a bulk load, inconsistent extraction and late reading are common problems. Use a representative sample, run controls and keep records.

Specification Detail
Sample Cereals and feed
Format Strip, single use
Result time Minutes after extraction
Storage Room temperature, dry
Confirmation LC-MS/MS

Where T-2 testing is used

Oat mills, barley processors, feed producers and importers screen T-2/HT-2 at receiving and before release. The strip is also useful when a cool, wet season raises the risk of Fusarium contamination.

Sampling oats and barley

Take multiple increments from the lot, grind the composite and extract according to the kit insert. Because trichothecenes can be unevenly distributed, a representative sample is more important than a large single probe.

Storage and controls

Keep strips dry, equilibrate to room temperature and run controls with each batch. Record the kit lot, sample ID and reading time. Store records so a buyer or auditor can trace the result to the lot.

When to confirm by laboratory

Confirm any positive or borderline result by LC-MS/MS. Because the EU uses indicative levels rather than legal maxima, agree the action level with the buyer before shipment.

How to choose the right T-2 kit

Confirm the validated matrix, cutoff and extraction. Oats and barley can behave differently from wheat, so ask for matrix-specific performance data. Check the kit's storage requirements and certificate of analysis, and choose a format that can measure below the action level agreed with the buyer.

Bottom line

T-2/HT-2 screening is most useful when it is linked to a sampling plan and a confirmation pathway. Because the EU uses indicative levels, agree the action level with the buyer and document every decision.

Should I test for both T-2 and HT-2?

Many rapid tests target T-2 with cross-reactivity to HT-2. Confirm the cross-reactivity and the total result with the kit supplier and, where needed, LC-MS/MS.

Sampling checklist for oats and barley

Take multiple increments from different depths and combine them. Grind the composite finely, mix thoroughly and extract according to the insert. Record lot, origin, harvest year and sampling date. Because trichothecenes can be unevenly distributed, do not rely on a single probe. Keep the sample and records until the lot is released, and confirm any positive or borderline result by LC-MS/MS.

Ordering and technical support

Conlight supplies this test as part of its rapid diagnostic range, with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Please confirm the final specifications and regulatory limits for your destination market before placing an order.

Important note

Rapid test results are screening information. Confirm any positive or borderline result with an accredited laboratory method before making a regulatory, export or treatment decision. Specifications, limits and kit performance can change; always use the current instructions and certificate of analysis supplied with the lot.

Frequently asked questions

Are T-2/HT-2 limits legal in the EU?

The EU uses indicative levels for cereals and cereal products; buyers may apply stricter specifications.

Can the strip test oats?

Check the validated matrices in the insert and use the recommended extraction.

How do I confirm a positive?

Send the sample to an accredited laboratory for LC-MS/MS analysis.

Sources and further reading

Explore the food safety testing range.

view detail
05

Fumonisin Rapid Test Strip

2025-10-22

Quick answer: A fumonisin rapid test strip screens maize, feed and grain for fumonisin residues in minutes after extraction, giving QA teams a fast presumptive result before laboratory confirmation.

Key takeaways

  • Fumonisins are mycotoxins produced by Fusarium moulds, mainly in maize.
  • The EU sets maximum levels for fumonisins in maize and maize products; the US FDA publishes guidance levels.
  • Rapid strips triage high-risk lots; confirm positives by HPLC or LC-MS/MS.
  • Monitor feed and storage conditions to reduce risk.

Why fumonisin matters

Fumonisins can contaminate maize, maize flour, grits and animal feed. High exposure has been associated with adverse health effects in animals and is a recognised food safety concern. Drought stress and poor storage increase the risk.

What the strip detects

The test uses a competitive immunoassay to detect fumonisin in the sample extract. A visible test line indicates a level below the kit cutoff; a faint or absent line is a presumptive positive.

US and EU rules at a glance

The EU sets maximum levels for fumonisins in unprocessed maize, maize flour, maize-based foods and feed under Regulation (EU) 2023/915. In the US, FDA publishes guidance levels for fumonisins in human food and animal feed.

How to use the strip

  • Grind a representative maize or feed sample.
  • Extract and dilute according to the insert.
  • Apply the extract and read in the specified window.
  • Hold positives for HPLC or LC-MS/MS.

Common mistakes

Using a non-representative sample, skipping the extraction step and reading late are common errors. Keep strips dry, run controls and document lot-level results for buyers.

Specification Detail
Sample Maize, maize products, feed
Format Strip, single use
Result time Minutes after extraction
Storage Room temperature, dry
Confirmation HPLC or LC-MS/MS

Where fumonisin testing is used

Maize mills, feed producers, snack manufacturers and importers screen fumonisins at receiving and before release. The strip is also useful during supplier audits and when a new origin or harvest year enters the supply chain.

How to take a representative maize sample

Fumonisin contamination is uneven. Take multiple increments from different depths, combine them and quarter the sample before grinding. A surface sample or a single probe can miss a hot spot and produce a misleading result.

Storage, controls and documentation

Keep strips sealed and dry, equilibrate them to room temperature and run a negative control with each batch. Record lot, origin, kit lot and result. If a lot is held, document the confirmation and disposition.

When to confirm by laboratory

Confirm positives, borderline results and a small subset of negatives by HPLC or LC-MS/MS. Review trends by origin and harvest year to adjust sampling frequency.

How to choose the right fumonisin kit

Check the validated matrix, the cutoff and the extraction method. A kit designed for maize flour may not be validated for whole maize or feed. Ask for the certificate of analysis, confirm the storage conditions and choose a format that can measure below the destination limit. For near-limit results, plan confirmation by HPLC or LC-MS/MS.

Bottom line

Fumonisin risk is driven by harvest and storage conditions. Combine representative sampling, rapid screening and laboratory confirmation to protect maize and feed shipments in both the US and EU markets.

Does the kit work for silage?

Check the validated matrices in the insert; silage and feed require specific extraction and validation.

Sampling checklist for maize lots

Take at least five to eight increments from different parts of the lot, combine them and quarter the composite. Grind the final sample finely and mix it thoroughly before extraction. Record the lot, origin, harvest year and sampling date. If the lot is large, sample at the rate defined in your plan and keep the increments identifiable. A representative sample is the single biggest factor in a reliable fumonisin result, and it protects both the buyer and the supplier.

Ordering and technical support

Conlight supplies this test as part of its rapid diagnostic range, with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Please confirm the final specifications and regulatory limits for your destination market before placing an order.

Frequently asked questions

What is the EU fumonisin limit?

Limits are product-specific in Regulation (EU) 2023/915; check unprocessed maize, flour and finished products separately.

Does the kit work for animal feed?

Check the validated matrix and extraction procedure in the kit insert.

Can a rapid strip replace a laboratory test?

No, it is a screening tool; confirmation is required for regulatory decisions.

Sources and further reading

Explore the food safety testing range.

view detail
06

Ochratoxin Rapid Test Strip

2025-10-22

Quick answer: An ochratoxin A rapid test strip screens cereals, coffee and feed for OTA residues in minutes after extraction, helping QA teams hold suspect lots before HPLC or LC-MS/MS confirmation.

Key takeaways

  • Ochratoxin A is a nephrotoxic mycotoxin found in cereals, coffee, grapes and feed.
  • The EU sets product-specific OTA maximum levels; the US relies on FDA guidance and monitoring.
  • Rapid strips are screening tools; confirm positives by HPLC.
  • Store strips dry and record kit lot and sample ID.

Why ochratoxin A matters

Ochratoxin A (OTA) is produced by Aspergillus and Penicillium moulds and can contaminate wheat, barley, maize, coffee, raisins and animal feed. Long-term exposure is linked to kidney damage, and regulators in the EU and US monitor cereals and processed foods closely.

What the rapid test strip detects

The strip uses a competitive immunochromatographic format. OTA in the sample extract competes with a fixed antigen on the test line, so a visible line indicates a low residue level and a faint or absent line suggests a presumptive positive.

US and EU rules at a glance

The EU sets maximum levels for OTA in unprocessed and processed cereals, coffee and other products under Regulation (EU) 2023/915. The US does not have a single general OTA limit; FDA guidance and monitoring programmes apply, and buyers may set their own specifications.

How to use the strip

  • Grind and homogenise the sample.
  • Extract with the specified solvent and dilute.
  • Apply the extract to the strip and read within the stated window.
  • Hold presumptive positives for HPLC or LC-MS/MS.

Common mistakes

Poor grinding, inconsistent extraction ratios and reading after the valid window are the main sources of error. Another is treating a screen as a certificate. Run controls, train operators and keep lot-level records.

Specification Detail
Sample Cereals, coffee, feed (per kit insert)
Format Strip, single use
Result time Minutes after extraction
Storage Room temperature, dry
Confirmation HPLC or LC-MS/MS

Where ochratoxin testing is used

Cereal mills, coffee roasters, raisin packers, feed producers and importers use OTA screening at receiving and before release. The strip is also useful during supplier audits, when a quick result helps decide whether a lot should be held for laboratory analysis.

How to validate the strip for your matrix

Recovery differs between wheat, maize, coffee and raisins. Run spiked samples, compare results with HPLC and record the validated cutoff for each matrix. Re-validate when the supplier, extraction method or product specification changes.

Record-keeping for buyers

Keep the sample ID, lot, origin, extraction date, kit lot, operator and result. If a lot is held, record the confirmation result and disposition. Buyers increasingly ask for this evidence during supplier approval and annual audits.

When to confirm by laboratory

Confirm any positive or borderline result, and send a small subset of negatives for verification. This keeps the screening programme honest and demonstrates that the rapid method is under control.

How to choose the right ochratoxin kit

Check the validated matrices first: a kit for wheat may not perform the same way on coffee or raisins. Confirm the cutoff, the extraction procedure and the storage conditions, and ask for a certificate of analysis for the lot. If the destination market has a very low limit, choose a kit that can measure below it and confirm near-limit results by HPLC.

Bottom line

Ochratoxin A screening works best as part of a documented programme: representative sampling, validated extraction, controls with every batch and confirmation of positives. That combination protects the lot, the brand and the export relationship.

Do I need a reader with the strip?

Visual strips are read by eye; quantitative formats need a compatible reader. Choose the format that matches the decision you need to make.

Quick application notes

Use the kit at receiving, during supplier audits and before release. Keep a written SOP, run a negative control with each batch and send any positive or borderline result to an accredited laboratory. Review results by origin and product type to adjust testing frequency.

Ordering and technical support

Conlight supplies this test as part of its rapid diagnostic range, with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Please confirm the final specifications and regulatory limits for your destination market before placing an order.

Frequently asked questions

Can the strip be used for export clearance?

No, it is a screening tool. Regulators and buyers require accredited confirmation for official decisions.

Does the kit work for coffee and cereals?

Check the validated matrices in the insert; extraction differs by matrix.

What is the EU OTA limit?

Limits are product-specific in Regulation (EU) 2023/915; check the exact product code.

Sources and further reading

Explore the food safety testing range.

view detail
07

Vomitoxin Rapid Quantitative Test Strip

2025-10-22

Quick answer: The Vomitoxin Rapid Quantitative Test Strip measures DON in wheat, barley, oats and feed after extraction, giving a quantitative presumptive result in minutes before LC-MS/MS confirmation.

Key takeaways

  • Vomitoxin (DON) is a Fusarium mycotoxin common in wheat, oats and maize.
  • The EU sets maximum levels for cereals and cereal products; the US FDA publishes advisory levels.
  • Quantitative strips support receiving decisions and supplier trends.
  • Confirm positives and borderline results by LC-MS/MS.

Why vomitoxin testing matters

Deoxynivalenol causes feed refusal, vomiting and reduced performance in livestock, and it is regulated in many markets. Wheat, barley, oats and maize are the main risk commodities, especially in cool, wet growing seasons. A positive lot can be rejected at the border or by the buyer.

What the strip detects

The strip uses a competitive immunoassay with a quantitative reader. DON in the extract competes with a fixed antigen on the test line, and the reader calculates the concentration. The result is a screening value, not a regulatory certificate; confirm near-limit and positive results by LC-MS/MS.

US and EU rules at a glance

The EU sets maximum levels for DON in unprocessed cereals, flour, bread, pasta and other products under Regulation (EU) 2023/915. The US FDA publishes advisory levels for finished wheat products and guidance for feed. These are not legal tolerances, but buyers often apply them as specifications.

How to use the strip

  • Take multiple increments and grind the composite.
  • Extract and dilute per the insert.
  • Apply the extract and read with the reader.
  • Confirm positives and borderline results by LC-MS/MS.

Common mistakes

Using a single probe, inconsistent extraction and late reading are frequent errors. Another is relying on a screen for a regulatory decision. Run controls, document kit lot and result, and review trends by origin and harvest year.

Specification Detail
Sample Wheat, barley, oats, feed
Format Quantitative strip with reader
Result time Minutes after extraction
Storage Room temperature, dry
Confirmation LC-MS/MS

Sampling and storage

DON contamination can be uneven, especially in grain with fusarium damage. Take multiple increments, quarter the composite and grind it finely. Record the harvest year, origin and storage history. Keep grain dry and ventilated, and retain a sample until the lot is released.

Documentation for buyers

Keep the sample ID, kit lot, result and disposition together. If a lot is held, record the LC-MS/MS confirmation and corrective action. Buyers increasingly ask for lot-level evidence during supplier approval and audits.

When to confirm by laboratory

Confirm positives and borderline results, and verify a subset of negatives. Review trends by origin and season to adjust testing frequency.

Field-to-storage checklist

Record the field, harvest date and weather. Dry grain promptly, clean equipment between lots and keep storage ventilated. Inspect for mould, insects and moisture before shipment, and sample the stored lot again before loading because conditions can change.

Key questions for suppliers

Ask for the harvest year, moisture record, storage history and previous DON results. Confirm the sampling method and laboratory used, and review trends rather than a single certificate.

Bottom line

DON risk is driven by weather and storage. Combine representative sampling, rapid screening and laboratory confirmation to protect wheat and oat shipments.

Quick facts

DON is a Fusarium mycotoxin, the EU sets maximum levels, the US publishes advisory levels, and LC-MS/MS confirms positive screens. Sampling is the biggest factor in a reliable result.

Important note

Rapid test results are screening information. Confirm any positive or borderline result with an accredited laboratory or veterinary method before making a regulatory, export or treatment decision. Specifications and kit performance can change; always use the current instructions and certificate of analysis supplied with the lot.

Handling and storage

Store the kit at room temperature in a dry place, keep the pouch sealed until use, equilibrate to room temperature before testing and do not use expired devices. Use the buffer and swabs supplied with the kit, follow the reading time exactly and record the kit lot and expiry date in the test record.

Frequently asked questions

What is the EU DON limit?

Limits are product-specific in Regulation (EU) 2023/915; check unprocessed cereals, flour and finished products.

Does the US have a DON limit?

The FDA publishes advisory levels for finished wheat products and feed; they are not legal tolerances.

Can a rapid test replace LC-MS/MS?

No, it is a screening tool; confirmation is required for official decisions.

Sources and further reading

Ordering and technical support

Conlight supplies this test with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Confirm the final specifications and regulatory limits for your destination market before ordering.

Explore the food safety testing range.

view detail
08

Zearalenone Rapid Quantitative Test Strip

2025-09-23

Quick answer: The Zearalenone Rapid Quantitative Test Strip measures ZEN in cereals and feed after extraction, giving a quantitative presumptive result in minutes so QA teams can hold suspect lots before LC-MS/MS confirmation.

Key takeaways

  • Zearalenone is an estrogenic mycotoxin found mainly in maize, wheat and feed.
  • The EU sets product-specific maximum levels; the US relies on FDA monitoring and buyer specifications.
  • Quantitative strips support receiving decisions and trend analysis.
  • Confirm positives and a subset of negatives by LC-MS/MS.

Why zearalenone testing matters

Zearalenone is produced by Fusarium moulds and can contaminate maize, wheat, barley and animal feed. It binds to estrogen receptors and can cause reproductive disorders in pigs and other livestock, and it is a regulated mycotoxin in the EU. For exporters, a positive lot can trigger rejection, recall or a buyer audit, so receiving controls matter.

What the strip detects

The strip uses a competitive immunochromatographic format with a quantitative reader. ZEN in the sample extract competes with a fixed antigen on the test line, and the reader converts the line intensity into a concentration. The result is a screening value that should be confirmed by LC-MS/MS when it is near or above the action level.

US and EU rules at a glance

The EU sets maximum levels for zearalenone in unprocessed cereals, cereal flour, bread and other products under Regulation (EU) 2023/915. The US does not have a general action level for human food; FDA monitoring and buyer specifications apply. Feed limits and guidance also differ by species and market.

How to use the strip

  • Take a representative sample and grind it finely.
  • Extract and dilute according to the kit insert.
  • Apply the extract and read with the compatible reader.
  • Hold positive or borderline results for LC-MS/MS.

Common mistakes

Testing only the surface of a bulk load, using an unvalidated extraction for the matrix and skipping reader calibration are common errors. Another is treating a screening value as a certificate. Run controls, train operators and keep lot-level records.

Specification Detail
Sample Cereals and feed
Format Quantitative strip with reader
Result time Minutes after extraction
Storage Room temperature, dry
Confirmation LC-MS/MS

Sampling and storage

Zearalenone is unevenly distributed in grain. Take multiple increments from different depths, combine and quarter the sample, then grind it finely. Keep the sample dry and cool and analyse it promptly. Record lot, origin and harvest year, and retain a sample until the lot is released.

Documentation for buyers

Keep the sample ID, extraction date, kit lot, reader calibration and result together. If a lot is held, record the LC-MS/MS confirmation and disposition. Buyers may ask for this evidence during supplier approval and annual audits.

When to confirm by laboratory

Confirm any positive or borderline result, and send a small subset of negatives for verification. Review trends by origin and harvest year to adjust testing frequency.

Regulatory checklist

Confirm the destination limit for each cereal product, the required sampling method and the laboratory method. Check the supplier's certificate of analysis, written specification and corrective-action process. Keep the contract specification, screening record and confirmation report together so a buyer can follow the lot from farm to container.

Key questions for suppliers

Ask for the harvest year, storage history, moisture record and previous zearalenone results. A supplier who can show a consistent monitoring record is easier to approve than one who provides only a single certificate.

Bottom line

Zearalenone screening works best as part of a documented programme: representative sampling, validated extraction, controls with every batch and LC-MS/MS confirmation of positives. That combination protects the lot, the brand and the export relationship.

Important note

Rapid test results are screening information. Confirm any positive or borderline result with an accredited laboratory or veterinary method before making a regulatory, export or treatment decision. Specifications and kit performance can change; always use the current instructions and certificate of analysis supplied with the lot.

Handling and storage

Store the kit at room temperature in a dry place, keep the pouch sealed until use, equilibrate to room temperature before testing and do not use expired devices. Use the buffer and swabs supplied with the kit, follow the reading time exactly and record the kit lot and expiry date in the test record.

Frequently asked questions

Can the strip be used for export clearance?

No, it is a screening tool. Regulators and buyers require accredited LC-MS/MS confirmation.

Does it work for maize and wheat?

Check the validated matrices and extraction in the insert; matrix performance can differ.

What is the EU ZEN limit?

Limits are product-specific in Regulation (EU) 2023/915; check the exact product code.

Sources and further reading

Ordering and technical support

Conlight supplies this test with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Confirm the final specifications and regulatory limits for your destination market before ordering.

Explore the food safety testing range.

view detail
09

Aflatoxin B1 Rapid Quantitative Test Strip

2025-09-23

Quick answer: The Aflatoxin B1 Rapid Quantitative Test Strip measures AFB1 in maize, peanuts, feed and other commodities after extraction, giving a quantitative presumptive result in minutes before HPLC or LC-MS/MS confirmation.

Key takeaways

  • Aflatoxin B1 is the most toxic aflatoxin and a common feed contaminant.
  • The EU sets feed and food maximum levels; the US uses FDA action levels.
  • Quantitative strips support receiving decisions and trend analysis.
  • Confirm positives and a subset of negatives by HPLC or LC-MS/MS.

Why aflatoxin B1 testing matters

Aflatoxin B1 is produced by Aspergillus moulds and can contaminate maize, peanuts, cottonseed and compound feed. It is the most toxic aflatoxin and can cause liver damage, reduced performance and immunosuppression in livestock. For dairy cows, part of the ingested B1 is converted to aflatoxin M1 and excreted in milk, so feed control protects the dairy supply chain as well. Exporters face rejection, recall or buyer audits when a lot exceeds the destination limit.

What the strip detects

The strip uses a competitive immunochromatographic format with a quantitative reader. AFB1 in the sample extract competes with a fixed antigen on the test line, and the reader converts the line intensity into a concentration. The result is a screening value, not a regulatory certificate; confirm positive and borderline results by HPLC or LC-MS/MS.

US and EU rules at a glance

The EU sets maximum levels for aflatoxin B1 in food and feed under Regulation (EU) 2023/915 and Directive 2002/32/EC. The US FDA publishes action levels for corn, peanuts, cottonseed and other feed ingredients, and suggests guidance for complete feed. State feed laws and buyer specifications may be stricter than the federal baseline.

How to use the strip

  • Take a representative sample and grind it finely.
  • Extract and dilute according to the kit insert.
  • Apply the extract and read with the compatible reader.
  • Hold positive or borderline results for HPLC or LC-MS/MS.

Common mistakes

Testing only the surface of a bulk load, using an unvalidated extraction for the matrix and skipping reader calibration are common errors. Another is treating a screening value as a certificate. Run controls, train operators and keep lot-level records.

Specification Detail
Sample Maize, peanuts, feed
Format Quantitative strip with reader
Result time Minutes after extraction
Storage Room temperature, dry
Confirmation HPLC or LC-MS/MS

Sampling and storage

Aflatoxin contamination is uneven, especially in maize and peanuts. Take multiple increments from different depths, combine and quarter the sample, then grind it finely. Keep the sample dry and cool and analyse it promptly. Record the lot, origin, harvest year and storage history, and retain a sample until the lot is released.

Documentation for buyers

Keep the sample ID, extraction date, kit lot, reader calibration and result together. If a lot is held, record the HPLC or LC-MS/MS confirmation and disposition. Buyers may ask for this evidence during supplier approval and annual audits.

Quick facts for feed producers

Aflatoxin B1 is the most toxic aflatoxin, the EU sets feed and food maximum levels, the US uses FDA action levels, and carry-over to milk makes dairy feed a priority.

Bottom line

Aflatoxin B1 screening works best as part of a documented programme: representative sampling, validated extraction, controls with every batch and laboratory confirmation of positives. That combination protects the lot, the animals and the export relationship.

Handling and storage

Store the kit at room temperature in a dry place, keep the pouch sealed until use, equilibrate to room temperature before testing and do not use expired devices. Use the buffer and swabs supplied with the kit, follow the reading time exactly and record the kit lot and expiry date in the test record.

Quick facts

Aflatoxin B1 is the most toxic aflatoxin, the EU sets feed and food limits, the US uses FDA action levels and HPLC or LC-MS/MS confirms positives.

Frequently asked questions

Can the strip be used for export clearance?

No, it is a screening tool; accredited confirmation is required for official decisions.

Does it work for peanut and maize?

Check the validated matrices and extraction in the insert; matrix performance can differ.

What is the EU AFB1 limit?

Limits are product-specific in Regulation (EU) 2023/915 and Directive 2002/32/EC; check the exact category.

Sources and further reading

Ordering and technical support

Conlight supplies this test with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Confirm the final specifications and regulatory limits for your destination market before ordering.

Important note

Rapid test results are screening information. Confirm any positive or borderline result with an accredited laboratory method before making a regulatory or export decision. Always use the current instructions and certificate of analysis supplied with the lot.

Explore the food safety testing range.

view detail
10

Aflatoxin M1 Rapid Quantitative Test Strip

2025-09-23

Quick answer: Aflatoxin M1 rapid quantitative strips measure the milk metabolite in minutes, helping dairies compare results with limits such as the EU's 0.05 µg/kg and hold contaminated loads before confirmatory HPLC testing.

Key takeaways

  • Aflatoxin M1 is a heat-stable metabolite of aflatoxin B1 in dairy feed.
  • Quantitative strips give a concentration, not just a positive or negative.
  • Confirm regulatory positives with HPLC or LC-MS/MS.

Aflatoxin M1 is a metabolite of aflatoxin B1 that can appear in milk when dairy cows consume contaminated feed. It is heat-stable, so pasteurisation does not remove it, and many markets set strict limits - the EU, for example, limits aflatoxin M1 in raw milk to 0.05 micrograms per kilogram.

Why quantitative screening matters

Qualitative strips tell you whether a residue is present; quantitative strips tell you how much. For dairy processors, that difference matters when a load is close to a regulatory limit or when results must be documented for customers and authorities.

How the aflatoxin M1 rapid quantitative test strip works

The strip is read with a compatible reader after a short incubation. A competitive immunoassay produces a signal that is converted into a concentration, so operators get a numerical result on site rather than waiting for a laboratory.

  • Sample: raw or processed milk
  • Result: quantitative concentration within minutes
  • Use: incoming milk screening, tanker checks, export documentation

Practical tips

Keep milk samples cool and test them promptly. Calibrate the reader, use the same pipetting scheme for every batch and re-test any result near the action level. Confirm regulatory positives with an accredited HPLC or LC-MS/MS method.

Where it fits in a dairy quality programme

Rapid quantitative testing is ideal at receiving bays and in tankers. It helps dairies reject contaminated loads before they enter silos, protecting finished products and brand reputation. Paired with feed monitoring for aflatoxin B1, it closes the loop from farm to dairy.

See the Aflatoxin M1 Rapid Quantitative Test Strip for details.

Specification Detail
Sample Raw or processed milk
Result Quantitative concentration within minutes
Reader Compatible strip reader required
Best use Receiving bay, tanker checks, export records
Action level Compare with the limit for your market (EU: 0.05 µg/kg)

How do dairies build a practical aflatoxin M1 monitoring plan?

Regulatory limits only matter if the dairy can act on them quickly. A practical plan connects feed risk, receiving testing and documented decisions.

Start with feed

Aflatoxin M1 in milk comes from aflatoxin B1 in feed. Drought stress, poor storage and humid conditions raise B1 risk in silage, maize and compound feed. Monitor feed ingredients and keep dry matter dry; reducing B1 intake is the most effective way to protect the milk tank.

Test at receiving

Screen tanker and bulk samples at the receiving bay, before milk enters the silo. Keep samples cool, test promptly and record the tanker, farm and time. Composite samples from several farms can hide a single contaminated load, so risk-based individual testing is useful for high-risk suppliers.

Act on results

Compare each quantitative result with the limit for the destination market. Hold any load above the action level, confirm it by HPLC or LC-MS/MS and reject or divert it according to your procedure. Do not blend a contaminated load to dilute the result without regulatory approval.

Document for buyers

Keep calibration records, reader outputs, sample identity and the disposition of every load. Buyers increasingly ask for batch-level evidence, and a clear record turns a routine test into a commercial advantage. Review trends monthly and adjust testing frequency for suppliers with repeated detections.

Common aflatoxin M1 testing mistakes

Testing only finished milk, ignoring feed quality and using a qualitative strip for a quantitative decision are frequent errors. Blending a contaminated load to dilute the result is also risky and may be illegal. Monitor feed, use a calibrated reader and confirm any result near the limit.

  • No seasonal risk review for feed and silage
  • Reader calibration skipped or undocumented
  • Tanker identity missing from the record
  • No follow-up when a supplier repeats a positive

Frequently asked questions

What is the EU limit for aflatoxin M1 in milk?

The EU limit for aflatoxin M1 in raw milk is 0.05 µg/kg. National and buyer limits can differ, so always confirm the specification for the destination market.

Does pasteurisation remove aflatoxin M1?

No. Aflatoxin M1 is heat-stable, so pasteurisation and normal processing do not remove it. Prevention starts with feed monitoring for aflatoxin B1.

Do I still need laboratory confirmation?

Yes. Rapid quantitative strips are for screening and decision support; an accredited laboratory method is needed for regulatory or contractual confirmation.

Sources and further reading

view detail
11

Salmonella

2025-09-23

Salmonella is a rapid test kit based on Colloidal Gold Immunoassay methodology, used to detect residues of Salmonella in Food/Dairy.

view detail
12

Escherichia coli O157

2025-09-23

Escherichia coli O157 is a rapid test kit based on Colloidal Gold Immunoassay methodology, used to detect residues of Escherichia coli O157 in Food/Dairy.