Quick answer: The Aflatoxin B1 Rapid Quantitative Test Strip measures AFB1 in maize, peanuts, feed and other commodities after extraction, giving a quantitative presumptive result in minutes before HPLC or LC-MS/MS confirmation.
Key takeaways
- Aflatoxin B1 is the most toxic aflatoxin and a common feed contaminant.
- The EU sets feed and food maximum levels; the US uses FDA action levels.
- Quantitative strips support receiving decisions and trend analysis.
- Confirm positives and a subset of negatives by HPLC or LC-MS/MS.
Why aflatoxin B1 testing matters
Aflatoxin B1 is produced by Aspergillus moulds and can contaminate maize, peanuts, cottonseed and compound feed. It is the most toxic aflatoxin and can cause liver damage, reduced performance and immunosuppression in livestock. For dairy cows, part of the ingested B1 is converted to aflatoxin M1 and excreted in milk, so feed control protects the dairy supply chain as well. Exporters face rejection, recall or buyer audits when a lot exceeds the destination limit.
What the strip detects
The strip uses a competitive immunochromatographic format with a quantitative reader. AFB1 in the sample extract competes with a fixed antigen on the test line, and the reader converts the line intensity into a concentration. The result is a screening value, not a regulatory certificate; confirm positive and borderline results by HPLC or LC-MS/MS.
US and EU rules at a glance
The EU sets maximum levels for aflatoxin B1 in food and feed under Regulation (EU) 2023/915 and Directive 2002/32/EC. The US FDA publishes action levels for corn, peanuts, cottonseed and other feed ingredients, and suggests guidance for complete feed. State feed laws and buyer specifications may be stricter than the federal baseline.
How to use the strip
- Take a representative sample and grind it finely.
- Extract and dilute according to the kit insert.
- Apply the extract and read with the compatible reader.
- Hold positive or borderline results for HPLC or LC-MS/MS.
Common mistakes
Testing only the surface of a bulk load, using an unvalidated extraction for the matrix and skipping reader calibration are common errors. Another is treating a screening value as a certificate. Run controls, train operators and keep lot-level records.
| Specification |
Detail |
| Sample |
Maize, peanuts, feed |
| Format |
Quantitative strip with reader |
| Result time |
Minutes after extraction |
| Storage |
Room temperature, dry |
| Confirmation |
HPLC or LC-MS/MS |
Sampling and storage
Aflatoxin contamination is uneven, especially in maize and peanuts. Take multiple increments from different depths, combine and quarter the sample, then grind it finely. Keep the sample dry and cool and analyse it promptly. Record the lot, origin, harvest year and storage history, and retain a sample until the lot is released.
Documentation for buyers
Keep the sample ID, extraction date, kit lot, reader calibration and result together. If a lot is held, record the HPLC or LC-MS/MS confirmation and disposition. Buyers may ask for this evidence during supplier approval and annual audits.
Quick facts for feed producers
Aflatoxin B1 is the most toxic aflatoxin, the EU sets feed and food maximum levels, the US uses FDA action levels, and carry-over to milk makes dairy feed a priority.
Bottom line
Aflatoxin B1 screening works best as part of a documented programme: representative sampling, validated extraction, controls with every batch and laboratory confirmation of positives. That combination protects the lot, the animals and the export relationship.
Handling and storage
Store the kit at room temperature in a dry place, keep the pouch sealed until use, equilibrate to room temperature before testing and do not use expired devices. Use the buffer and swabs supplied with the kit, follow the reading time exactly and record the kit lot and expiry date in the test record.
Quick facts
Aflatoxin B1 is the most toxic aflatoxin, the EU sets feed and food limits, the US uses FDA action levels and HPLC or LC-MS/MS confirms positives.
Frequently asked questions
Can the strip be used for export clearance?
No, it is a screening tool; accredited confirmation is required for official decisions.
Does it work for peanut and maize?
Check the validated matrices and extraction in the insert; matrix performance can differ.
What is the EU AFB1 limit?
Limits are product-specific in Regulation (EU) 2023/915 and Directive 2002/32/EC; check the exact category.
Sources and further reading
Ordering and technical support
Conlight supplies this test with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Confirm the final specifications and regulatory limits for your destination market before ordering.
Important note
Rapid test results are screening information. Confirm any positive or borderline result with an accredited laboratory method before making a regulatory or export decision. Always use the current instructions and certificate of analysis supplied with the lot.
Explore the food safety testing range.
view