Inquiry
Form loading...

Zearalenone Rapid Quantitative Test Strip

Quick answer: The Zearalenone Rapid Quantitative Test Strip measures ZEN in cereals and feed after extraction, giving a quantitative presumptive result in minutes so QA teams can hold suspect lots before LC-MS/MS confirmation.

Key takeaways

  • Zearalenone is an estrogenic mycotoxin found mainly in maize, wheat and feed.
  • The EU sets product-specific maximum levels; the US relies on FDA monitoring and buyer specifications.
  • Quantitative strips support receiving decisions and trend analysis.
  • Confirm positives and a subset of negatives by LC-MS/MS.

Why zearalenone testing matters

Zearalenone is produced by Fusarium moulds and can contaminate maize, wheat, barley and animal feed. It binds to estrogen receptors and can cause reproductive disorders in pigs and other livestock, and it is a regulated mycotoxin in the EU. For exporters, a positive lot can trigger rejection, recall or a buyer audit, so receiving controls matter.

What the strip detects

The strip uses a competitive immunochromatographic format with a quantitative reader. ZEN in the sample extract competes with a fixed antigen on the test line, and the reader converts the line intensity into a concentration. The result is a screening value that should be confirmed by LC-MS/MS when it is near or above the action level.

US and EU rules at a glance

The EU sets maximum levels for zearalenone in unprocessed cereals, cereal flour, bread and other products under Regulation (EU) 2023/915. The US does not have a general action level for human food; FDA monitoring and buyer specifications apply. Feed limits and guidance also differ by species and market.

How to use the strip

  • Take a representative sample and grind it finely.
  • Extract and dilute according to the kit insert.
  • Apply the extract and read with the compatible reader.
  • Hold positive or borderline results for LC-MS/MS.

Common mistakes

Testing only the surface of a bulk load, using an unvalidated extraction for the matrix and skipping reader calibration are common errors. Another is treating a screening value as a certificate. Run controls, train operators and keep lot-level records.

Specification Detail
Sample Cereals and feed
Format Quantitative strip with reader
Result time Minutes after extraction
Storage Room temperature, dry
Confirmation LC-MS/MS

Sampling and storage

Zearalenone is unevenly distributed in grain. Take multiple increments from different depths, combine and quarter the sample, then grind it finely. Keep the sample dry and cool and analyse it promptly. Record lot, origin and harvest year, and retain a sample until the lot is released.

Documentation for buyers

Keep the sample ID, extraction date, kit lot, reader calibration and result together. If a lot is held, record the LC-MS/MS confirmation and disposition. Buyers may ask for this evidence during supplier approval and annual audits.

When to confirm by laboratory

Confirm any positive or borderline result, and send a small subset of negatives for verification. Review trends by origin and harvest year to adjust testing frequency.

Regulatory checklist

Confirm the destination limit for each cereal product, the required sampling method and the laboratory method. Check the supplier's certificate of analysis, written specification and corrective-action process. Keep the contract specification, screening record and confirmation report together so a buyer can follow the lot from farm to container.

Key questions for suppliers

Ask for the harvest year, storage history, moisture record and previous zearalenone results. A supplier who can show a consistent monitoring record is easier to approve than one who provides only a single certificate.

Bottom line

Zearalenone screening works best as part of a documented programme: representative sampling, validated extraction, controls with every batch and LC-MS/MS confirmation of positives. That combination protects the lot, the brand and the export relationship.

Important note

Rapid test results are screening information. Confirm any positive or borderline result with an accredited laboratory or veterinary method before making a regulatory, export or treatment decision. Specifications and kit performance can change; always use the current instructions and certificate of analysis supplied with the lot.

Handling and storage

Store the kit at room temperature in a dry place, keep the pouch sealed until use, equilibrate to room temperature before testing and do not use expired devices. Use the buffer and swabs supplied with the kit, follow the reading time exactly and record the kit lot and expiry date in the test record.

Frequently asked questions

Can the strip be used for export clearance?

No, it is a screening tool. Regulators and buyers require accredited LC-MS/MS confirmation.

Does it work for maize and wheat?

Check the validated matrices and extraction in the insert; matrix performance can differ.

What is the EU ZEN limit?

Limits are product-specific in Regulation (EU) 2023/915; check the exact product code.

Sources and further reading

Ordering and technical support

Conlight supplies this test with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Confirm the final specifications and regulatory limits for your destination market before ordering.

Explore the food safety testing range.

    Zearalenone Rapid Quantitative Test Strip is a highly toxic natural mycotoxin that may cause liver cancer, immune suppression, and serious food/feed safety issues.
    Suitable for livestock farming, agricultural product testing, food production, and regulatory inspections.
    Zearalenone Rapid Quantitative Test Strip Rapid Test Kit - Fluorescent Immunoassay - For Food、Feed, etc.

    ✅ Quick detection of Zearalenone Rapid Quantitative Test Strip residues in Food、Feed, etc.
    ✅ Based on Fluorescent Immunoassay for accuracy and ease of use.
    ✅ Ensures food/feed safety through fast results.
    ✅ Ideal for farm, factory, inspection site or lab.
    ✅ Shelf-stable format, ready to use anytime.


    Zearalenone Rapid Quantitative Test Strip is a rapid test kit based on Fluorescent Immunoassay methodology, used to detect residues of Zearalenone Rapid Quantitative Test Strip in Food、Feed, etc.. Zearalenone Rapid Quantitative Test Strip is a highly toxic natural mycotoxin that may cause liver cancer, immune suppression, and serious food/feed safety issues. Suitable for livestock farming, agricultural product testing, food production, and regulatory inspections.
    Zearalenone Rapid Quantitative Test Strip (4).jpg