Quick answer: An ochratoxin A rapid test strip screens cereals, coffee and feed for OTA residues in minutes after extraction, helping QA teams hold suspect lots before HPLC or LC-MS/MS confirmation.
Key takeaways
- Ochratoxin A is a nephrotoxic mycotoxin found in cereals, coffee, grapes and feed.
- The EU sets product-specific OTA maximum levels; the US relies on FDA guidance and monitoring.
- Rapid strips are screening tools; confirm positives by HPLC.
- Store strips dry and record kit lot and sample ID.
Why ochratoxin A matters
Ochratoxin A (OTA) is produced by Aspergillus and Penicillium moulds and can contaminate wheat, barley, maize, coffee, raisins and animal feed. Long-term exposure is linked to kidney damage, and regulators in the EU and US monitor cereals and processed foods closely.
What the rapid test strip detects
The strip uses a competitive immunochromatographic format. OTA in the sample extract competes with a fixed antigen on the test line, so a visible line indicates a low residue level and a faint or absent line suggests a presumptive positive.
US and EU rules at a glance
The EU sets maximum levels for OTA in unprocessed and processed cereals, coffee and other products under Regulation (EU) 2023/915. The US does not have a single general OTA limit; FDA guidance and monitoring programmes apply, and buyers may set their own specifications.
How to use the strip
- Grind and homogenise the sample.
- Extract with the specified solvent and dilute.
- Apply the extract to the strip and read within the stated window.
- Hold presumptive positives for HPLC or LC-MS/MS.
Common mistakes
Poor grinding, inconsistent extraction ratios and reading after the valid window are the main sources of error. Another is treating a screen as a certificate. Run controls, train operators and keep lot-level records.
| Specification |
Detail |
| Sample |
Cereals, coffee, feed (per kit insert) |
| Format |
Strip, single use |
| Result time |
Minutes after extraction |
| Storage |
Room temperature, dry |
| Confirmation |
HPLC or LC-MS/MS |
Where ochratoxin testing is used
Cereal mills, coffee roasters, raisin packers, feed producers and importers use OTA screening at receiving and before release. The strip is also useful during supplier audits, when a quick result helps decide whether a lot should be held for laboratory analysis.
How to validate the strip for your matrix
Recovery differs between wheat, maize, coffee and raisins. Run spiked samples, compare results with HPLC and record the validated cutoff for each matrix. Re-validate when the supplier, extraction method or product specification changes.
Record-keeping for buyers
Keep the sample ID, lot, origin, extraction date, kit lot, operator and result. If a lot is held, record the confirmation result and disposition. Buyers increasingly ask for this evidence during supplier approval and annual audits.
When to confirm by laboratory
Confirm any positive or borderline result, and send a small subset of negatives for verification. This keeps the screening programme honest and demonstrates that the rapid method is under control.
How to choose the right ochratoxin kit
Check the validated matrices first: a kit for wheat may not perform the same way on coffee or raisins. Confirm the cutoff, the extraction procedure and the storage conditions, and ask for a certificate of analysis for the lot. If the destination market has a very low limit, choose a kit that can measure below it and confirm near-limit results by HPLC.
Bottom line
Ochratoxin A screening works best as part of a documented programme: representative sampling, validated extraction, controls with every batch and confirmation of positives. That combination protects the lot, the brand and the export relationship.
Do I need a reader with the strip?
Visual strips are read by eye; quantitative formats need a compatible reader. Choose the format that matches the decision you need to make.
Quick application notes
Use the kit at receiving, during supplier audits and before release. Keep a written SOP, run a negative control with each batch and send any positive or borderline result to an accredited laboratory. Review results by origin and product type to adjust testing frequency.
Ordering and technical support
Conlight supplies this test as part of its rapid diagnostic range, with OEM/ODM options and export documentation for US and EU buyers. Contact the team for a quote, validation data, matrix guidance and the current certificate of analysis. Please confirm the final specifications and regulatory limits for your destination market before placing an order.
Frequently asked questions
Can the strip be used for export clearance?
No, it is a screening tool. Regulators and buyers require accredited confirmation for official decisions.
Does the kit work for coffee and cereals?
Check the validated matrices in the insert; extraction differs by matrix.
What is the EU OTA limit?
Limits are product-specific in Regulation (EU) 2023/915; check the exact product code.
Sources and further reading
Explore the food safety testing range.
view
detail